Safety & Security Analysis

GUIDE · SAFETY & SECURITY ANALYSIS

Disclaimer

Syscribe is a modeling and documentation tool provided "as-is" without warranty of any kind. The authors and contributors accept no responsibility or liability for the use of this tool in safety-critical, life-critical, or mission-critical applications.

Output from Syscribe — including validation results, generated templates, traceability reports, and analysis artifacts — must be independently reviewed and verified by qualified engineers before use in any certification, regulatory submission, or safety case. Compliance with standards such as ISO 26262, IEC 61508, ISO 13849-1, ISO/SAE 21434, IEC 61025, DO-178C, or any other functional safety or cybersecurity standard remains the sole responsibility of the user and their organisation.

This tool does not replace a certified safety process, a qualified safety engineer, or a formal assessment body.

Syscribe provides first-class support for four standard safety and security analysis methods. Each maps to a dedicated set of element types with validated required fields, stable IDs, enum-checked parameters, and cross-reference rules enforced at validation time.

Method Standard Element types ID patterns
HARA ISO 26262 / IEC 61508 / ISO 13849-1 HazardousEvent, SafetyGoal HE-*, SG-*
TARA ISO/SAE 21434 TARASheet → DamageScenario, ThreatScenario, CybersecurityGoal, SecurityControl TARA-*, DS-*, TS-*, CSG-*, SC-*
FTA IEC 61025 / ISO 26262-9 FaultTree, FaultTreeGate, FaultTreeEvent FT-*, FTG-*, FTE-*
FMEA IEC 60812 / SAE J1739 FMEASheet → FMEAEntry FMEA-*, FM-*
APA ISO/SAE 21434 §15.7 AttackTree, AttackTreeGate, AttackStep AT-*, ATG-*, ATS-*

Hazard and Risk Analysis (HARA)

Integrity level standards

Syscribe supports three functional safety standards on the same HazardousEvent / SafetyGoal element pair. They differ only in the risk parameters used to derive the integrity level target.

Standard Domain Risk input parameters Integrity level field
ISO 26262 Automotive severity S0–S3 · exposure E0–E4 · controllability C0–C3 asilLevel A–D
IEC 61508 General E/E/ES consequence Ca–Cd · freqExposure Fa/Fb · avoidance Pa/Pb · demandRate W1–W3 silLevel 1–4
ISO 13849-1 Machinery — (architecture Category assessed separately) plLevel a–e

All parameters are optional and independent — use the set that matches your domain. W801 fires when a SafetyGoal has none of asilLevel, silLevel, or plLevel set.

ASIL derivation. For ISO 26262 the ASIL is computed from severity/exposure/controllability with the ISO 26262-3 Table 4 (S0, E0 or C0 gives QM; otherwise the sum S+E+C of 10/9/8/7 gives D/C/B/A, lower is QM). syscribe show prints it as derivedASIL on a HazardousEvent and, as the maximum over its hazardousEvents:, on a SafetyGoal. A SafetyGoal whose asilLevel is lower than the derived value raises W811. A HazardousEvent with only some of S/E/C raises W813 (cannot derive), and one mixing ISO 26262 and IEC 61508 parameters raises W814. A SafetyGoal at ASIL C/D or SIL 3/4 without safeState: or ftti: raises W812; ftti: must be a number plus unit (ns, us, ms, s, min, h), else E880.

ASIL decomposition

asilLevel accepts QM, A, B, C, D. When requirements derived from one parent form a decomposition (every child lower, a QM channel, or decomposedFrom:), the channels must be an allowed ISO 26262-9 pair: D = C+A | B+B | D+QM, C = B+A | C+QM, B = A+A | B+QM, A = A+QM (E878), must be at least two (W860) and must satisfy distinct elements (E865) — at every level, not only D. Write the ISO notation directly: asilLevel: D(D) and asilLevel: QM(D) (quote the value if your editor objects), or the explicit field decomposedFrom: D; E879 flags an invalid original level.

HazardousEvent

---
type: HazardousEvent
id: HE-BRAKE-001
name: "Unintended brake release during high-speed cornering"
status: draft

# ISO 26262 — automotive
severity: S3          # S0 no injury | S1 light | S2 severe | S3 life-threatening
exposure: E3          # E0 incredibly unlikely … E4 high probability
controllability: C2   # C0 controllable | C1 simply | C2 normally | C3 uncontrollable
operationalSituation: "Vehicle traveling >80 km/h on curved road"

# IEC 61508 — non-automotive (use instead of S/E/C)
# consequence: Cc     # Ca slight | Cb serious | Cc death of one | Cd death of several
# freqExposure: Fb    # Fa rare/unlikely | Fb frequent/likely
# avoidance: Pb       # Pa possible | Pb barely possible
# demandRate: W3      # W1 very slight | W2 slight | W3 relatively high
---

Loss of brake hydraulic pressure due to solenoid valve failure allows
uncontrolled lateral drift at speed.

Required fields: id (HE-* pattern), name, status. All risk parameters are optional but at least one set should be present for the analysis to be meaningful.

SafetyGoal

---
type: SafetyGoal
id: SG-BRAKE-001
name: "Prevent unintended brake release during vehicle motion"
status: draft

# ISO 26262
asilLevel: D

# IEC 61508 alternative
# silLevel: 3

# ISO 13849-1 alternative
# plLevel: e

safeState: "Both brake circuits remain engaged"
ftti: "50ms"
hazardousEvents:
  - HE-BRAKE-001
---

The brake system shall maintain hydraulic pressure on both axles at all
times during vehicle motion unless commanded by the driver.

hazardousEvents: must each resolve to a HazardousEvent element (E825). W801 fires if no integrity level field is set. W800 fires if a HazardousEvent is not referenced by any SafetyGoal, unless its S/E/C derive QM (no goal required).

Generating templates

syscribe -m model/ template HazardousEvent > Safety/HARA/HE-BRAKE-001.md
syscribe -m model/ template SafetyGoal     > Safety/HARA/SG-BRAKE-001.md

Threat Analysis and Risk Assessment (TARA)

Sheet-level common fields. A TARASheet (and an FMEASheet) can state responsibility, appliesWhen and tags once; every exploded row inherits them unless the row sets its own (TARA rows only — a row's tags list replaces the sheet's). FMEA entries have no per-row keys for these and always inherit. Inheriting appliesWhen is what gates the rows in a projected variant; the copy is not re-validated per row (only the sheet is). Upgrading note: row content now includes the inherited values, so a baseline sealed over such rows needs re-sealing.

The TARASheet is an exploded container (Option B). You write one file holding four section tables; the parser synthesises a first-class element for each row at parse time, so all cross-reference checks, graph edges, and validation rules apply automatically.

---
type: TARASheet
id: TARA-SYS-001
name: "TARA — Vehicle ECU communication bus"
status: draft

damageTable:
  - id: DS-SYS-001
    name: "Unauthorized command injection causes vehicle manoeuvre"
    damageSeverity: severe
    impactCategories: [safety, operational]
    hazardRef: SG-SYS-001        # the SafetyGoal this damage can violate (W030 if absent)

threatTable:
  - id: TS-SYS-001
    name: "Attacker replays CAN frame via OBD-II port"
    attackFeasibility: medium
    attackVector: local
    damageScenarios: [DS-SYS-001]

goalTable:
  - id: CSG-SYS-001
    name: "Ensure integrity of safety-critical CAN messages"
    calLevel: CAL4               # severe × medium feasibility = critical risk → CAL4 (W032)
    securityProperty: integrity
    threatScenarios: [TS-SYS-001]

controlTable:
  - id: SC-SYS-001
    name: "Implement message authentication (MAC) on safety bus"
    controlType: prevention
    implementsGoals: [CSG-SYS-001]
---

Each synthesised element (DS-SYS-001, TS-SYS-001, etc.) is visible in the model browser and individually addressable by stable ID. Standalone element files (DamageScenario, ThreatScenario, etc.) are also accepted and follow the same validation rules.

Generating a template

syscribe -m model/ template TARASheet > Safety/TARA-SYS-001.md

Safety ↔ Security co-engineering (ISO 26262 ⇄ ISO/SAE 21434)

Syscribe holds both the functional-safety layer (HazardousEvent, SafetyGoal) and the cybersecurity layer (DamageScenario, ThreatScenario, …) in one model. A dual functional-safety + cybersecurity assessor's first question is "which cyber threats can violate a safety goal, and where is that analysed?" The hazardRef cross-link and the co-analysis view answer it.

A DamageScenario (or a ThreatScenario) may declare hazardRef: pointing to the HazardousEvent/SafetyGoal it endangers. The value is a single string or a list, resolved by id or qualified name. It is the bridge between the two analyses:

ThreatScenario --damageScenarios--> DamageScenario --hazardRef--> HazardousEvent/SafetyGoal
# standalone DamageScenario (or a damageTable row)
type: DamageScenario
id: DS-SYS-001
name: "Unauthorized command injection causes vehicle manoeuvre"
status: draft
damageSeverity: severe
impactCategories: [safety, operational]
hazardRef: SG-SYS-001          # the SafetyGoal this damage can violate

A ThreatScenario may carry its own direct hazardRef when it threatens a hazard/goal without an intervening damage scenario.

Validation:

  • E844 — a hazardRef value that does not resolve, or resolves to an element that is not a HazardousEvent/SafetyGoal, is an error.
  • W030 — a DamageScenario whose impactCategories includes safety but has no hazardRef is the cross-domain gap an assessor flags first. It is a warning, opt-in (only fires for safety-tagged damage scenarios) and gateable with --deny W030.

co-analysis — the cross-domain view

syscribe -m model/ co-analysis            # readable grouped report
syscribe -m model/ co-analysis --json     # structured document

For each SafetyGoal/HazardousEvent that is a hazardRef target, the view lists the safety-relevant DamageScenarios linked to it and, transitively, the ThreatScenarios that lead to them — which cyber threats can violate this safety goal/hazard. A final section lists the safety-tagged DamageScenarios with no hazardRef (the W030 gaps). The --json form is { goals: [{ id, type, damageScenarios, threats }], unlinkedSafetyDamage: [...] }. With no relevant content the command prints a notice and exits 0.

Deferred (future work): the reverse check — a SafetyGoal whose realising architecture has an attack surface with no security consideration — requires goal→architecture→vulnerability reachability and is not yet implemented (GH #28 check (b)).

Cybersecurity risk determination (ISO/SAE 21434 §15.8–15.9)

Each ThreatScenario has a computed risk level derived from the severity of the damage it can cause and how feasible the attack is:

  • severity rank — negligible=0, moderate=1, major=2, severe=3 — the max damageSeverity over the DamageScenarios the threat names in damageScenarios (resolved by id / qualified name). Unknown if none resolve or none carry a severity.
  • feasibility rank — very_low=0, low=1, medium=2, high=3 (from attackFeasibility). Unknown if missing/invalid.
  • if either rank is unknown the risk is unknown (listed but never gated); otherwise score = severity + feasibility (0..6) maps to low (0–1), medium (2–3), high (4) or critical (5–6).

Configurable (GH #222). The rank-sum above is the default simple method. A [cyber] table in .syscribe.toml can select an annex method (built-in example tables modelled on the ISO/SAE 21434 informative annexes — not normative, verify against your copy of the standard), override matrix/CAL cells, derive attackFeasibility from attack-potential factors (elapsedTime, expertise, knowledge, windowOfOpportunity, equipment) and rate impact per category (safetyImpact, financialImpact, operationalImpact, privacyImpact; overall = max). See the ISO/SAE 21434 guide. Codes: W640, W641, W642, E640, E641.

Record the risk-treatment decision on the threat:

type: ThreatScenario
id: TS-SYS-001
name: "Attacker replays CAN frame via OBD-II port"
status: draft
attackFeasibility: high
damageScenarios:
  - DS-SYS-001          # severe → critical risk
riskTreatment: reduce   # avoid | reduce | share | retain  (invalid → E845)
residualRisk: Low after message authentication on torque frames   # free text

Validation:

  • E845 — riskTreatment is not one of avoid/reduce/share/retain.
  • W031 — a ThreatScenario whose computed risk is high/critical has no riskTreatment and is not addressed by any CybersecurityGoal (none lists it in threatScenarios). A warning (exit code unchanged), gateable with --deny W031 and promotable to error via a [profiles] policy. Add a riskTreatment or an addressing CybersecurityGoal to clear it.
  • W032 — a CybersecurityGoal's calLevel is below the expected minimum CAL for the max risk of the threats it lists (low→CAL1, medium→CAL2, high→CAL3, critical→CAL4). Warning, gateable with --deny W032.

cyber-risk — the risk-determination view

syscribe -m model/ cyber-risk            # Markdown table
syscribe -m model/ cyber-risk --json     # JSON array
syscribe -m model/ cyber-risk --format html   # TARA heat table (md|html|json)

Lists each ThreatScenario with its severity, feasibility, computed risk level, riskTreatment (or —), addressed-by-goal (yes/no), and a flag (untreated when it trips W031, unknown when risk is not computable, else ok). The --json form is an array of {id, severity, feasibility, risk, treatment, addressed, flag}. With no ThreatScenarios the command prints a notice and exits 0.

Heat tables (FMEA, HARA, TARA)

A heat table is a grid of an analysis' two axes with the elements placed in their cells, so concentrations of risk are visible at a glance. Colour is never the only signal: every cell also prints its text label (product and band, ASIL letter, or risk level).

syscribe -m model/ fmea report --format md       # severity x occurrence, RPN-banded failure modes
syscribe -m model/ hara matrix --format html     # S/E rows x C columns -> ASIL, events and goals placed
syscribe -m model/ cyber-risk --format json      # impact x feasibility under the configured [cyber] method
View Rows x columns Cell Placed elements
FMEA severity 10..1 x occurrence 1..10 severity x occurrence product, toned (>=50 critical, >=20 high, >=8 medium) each FMEAEntry with its RPN, coloured by RPN band (>=200 critical, >=100 high, >=50 medium)
HARA S1-S3 x E1-E4 by C1-C3 ASIL from ISO 26262-3 Table 4 (QM, A, B, C, D) HazardousEvents in their S/E/C cell; a SafetyGoal (marked goal) in the cell of its highest-ASIL event
TARA impact severe..negligible x feasibility very_low..high risk level of the configured method (with the matrix value for annex) each ThreatScenario

Elements that cannot be placed (missing or invalid axis values, S0/E0/C0 events, threats with unknown impact or feasibility) are listed under "Not placed" instead of being dropped. --format html writes a standalone page (inline CSS, no scripts, no network); --format json emits {title, rows, cols, legend, cells[{row, col, label, tone, elements}], unplaced} with tones ok|low|medium|high|critical. export-html adds the three grids as reports/heat.html, and syscribe-server serves them at /heat. The default text output and --json of fmea report and cyber-risk are unchanged.


Fault Tree Analysis (FTA)

FTA uses the file-per-element (Option A) pattern. Each node is its own .md file. The three element types map directly to standard FTA constructs.

Directory layout

Gates and events must be nested inside a subdirectory named after the FaultTree file. The validator checks for children by qualified-name prefix (W900), so a flat layout where all files share the same parent directory will not satisfy the check.

Safety/FTA/
  FT-BRAKE-001.md               ← FaultTree
  FT-BRAKE-001/
    FTG-BRAKE-001.md            ← top-level OR gate
    FTG-BRAKE-002.md            ← sub-gate
    FTE-BRAKE-001.md            ← basic event
    FTE-BRAKE-002.md

This produces qualified names:

File Qualified name
FT-BRAKE-001.md Safety::FTA::FT-BRAKE-001
FT-BRAKE-001/FTG-BRAKE-001.md Safety::FTA::FT-BRAKE-001::FTG-BRAKE-001
FT-BRAKE-001/FTE-BRAKE-001.md Safety::FTA::FT-BRAKE-001::FTE-BRAKE-001

W900 fires if no FaultTreeGate or FaultTreeEvent element has a qualified name prefixed by the FaultTree's own qname.

FaultTree

---
type: FaultTree
id: FT-BRAKE-001
name: "Fault tree — brake system loss of control"
status: draft
topEvent: Safety::SG-BRAKE-001   # must resolve to a SafetyGoal (E902)
# missionTime: "1e9 h"
---

FaultTreeGate

---
type: FaultTreeGate
id: FTG-BRAKE-001
name: "OR gate — hydraulic failure paths"
gateType: OR           # AND | OR | XOR | NOT | inhibit
inputs:
  - FTG-BRAKE-002      # child gate
  - FTE-BRAKE-001      # leaf event
---

gateType must be one of AND, OR, XOR, NOT, inhibit (E905). All inputs: must resolve to FaultTreeGate or FaultTreeEvent elements (E906). A gate with no inputs fires W901.

FaultTreeEvent

---
type: FaultTreeEvent
id: FTE-BRAKE-001
name: "Primary solenoid valve — total failure"
eventKind: basic          # basic | undeveloped | house
ref: Braking::SolenoidValve
failureRate: 1.0e-9       # failures per hour (λ)
diagnosticCoverage: 0.99        # DC, 0.0–1.0 — fraction detected by a safety mechanism
latentDiagnosticCoverage: 0.90  # DCl, 0.0–1.0 — fraction of the latent part covered
---

eventKind values: basic (quantifiable leaf), undeveloped (not yet analysed), house (assumed event).

The optional ref: field links the event to the model element whose failure it represents — typically a Part/PartDef, written as a qualified name or a stable id. It is resolved like any other cross-reference; a ref: that does not resolve is E927. The link is shown by show <FTE-id>, listed by links in both directions (the element lists the event as an inbound ref), carried in the element graph as a faultTreeEventRef edge, and printed on a second line of the event's node in fault-tree render.

diagnosticCoverage (DC) and latentDiagnosticCoverage (DCl) are the FMEDA inputs to the quantitative metrics roll-up below. Both are optional and must lie in 0.0–1.0 (else E846).


Fault-tree analysis — fault-tree analyze

A FaultTree is a Boolean model: the top node (the one gate or event no other node references) occurs when its inputs combine per their gateType. syscribe -m model/ fault-tree analyze <FT-id> evaluates it:

syscribe -m model/ fault-tree analyze FT-BRAKE-001            # Markdown report
syscribe -m model/ fault-tree analyze FT-BRAKE-001 --json     # cutSets, events, topProbability, …
syscribe -m model/ fault-tree analyze FT-BRAKE-001 --max-order 3 --no-ccf

It reports:

  • Minimal cut sets — the smallest sets of basic events whose joint occurrence causes the top event, with their order (1 = single point of failure, 2 = dual point, …) and probability. AND and inhibit gates conjoin their inputs (an inhibit gate's last input is the conditioning event), OR disjoins, XOR is parity, NOT negates its single input. house events are constants (TRUE only at probability: 1); basic and undeveloped events are variables.
  • Top-event probability over the tree's missionTime — exact (computed from a reduced ordered BDD, so shared events are handled correctly) plus the rare-event and min-cut-upper-bound approximations. An event's probability is its explicit probability:, otherwise 1 − e^(−λ·t) from failureRate (λ, /h) and missionTime ("8760 h", "1e9 h", "10 y"). If an event in the analysis has neither, the probability is n/a and the report says which events lack one. A gate's own probability: is informational and ignored.
  • Importance per event — Fussell-Vesely (share of the top-event probability involving the event), Birnbaum (∂P/∂p) and RAW (risk achievement worth) — and a role: single_point, dual_point, multi_point, irrelevant (in no cut set), unreachable (not below the top node) or house.
  • Common-cause failure (beta factor). Give two or more events the same ccfGroup: and a ccfBeta: (0.0–1.0). Each member is replaced by OR(member_independent, CCF:<group>) with P(independent) = (1−β)·p and P(CCF) = β·mean(p), so a redundant AND pair shows the common-cause event as an order-1 cut set. --no-ccf switches the expansion off.
type: FaultTreeEvent
id: FTE-BRAKE-002
name: "Redundant valve B stuck"
eventKind: basic
failureRate: 1.0e-7
ccfGroup: VALVES      # shared with FTE-BRAKE-001
ccfBeta: 0.1

The same analysis is a public library API (syscribe_model::fta) reused by metrics and by diagram tooling. A tree that has events but no gates is treated as an implicit OR of its events (legacy flat form).

Structural checks (validate): a gate cycle or self-input is E980; NOT with more than one input, XOR with more than two, or an inhibit gate without a conditioning input is E981; a negative failureRate E982; a probability outside 0–1 E983; a ccfBeta outside 0–1 E984; a gate/event not reachable from the top node W980; one outside any FaultTree directory W981; a single-input AND/OR W982; a one-member ccfGroup W983; a ccfGroup with missing or inconsistent betas W984; an unparsable missionTime W987.


Quantitative HW safety metrics (ISO 26262-5 §8–9) — metrics

First-order approximation. This is a first-order, FMEDA-style roll-up driven entirely by your failureRate and diagnostic-coverage inputs. It is not a substitute for a full FMEDA and must be independently verified before use in a hardware safety case.

For each SafetyGoal, the tool analyses the FaultTree(s) whose topEvent resolves to that goal (see Fault-tree analysis) and uses the minimal cut sets, so gate logic matters: AND(a,b) and OR(a,b) over the same events give different metrics. Only reachable, non-house events that appear in a cut set and declare a non-negative failureRate (λ, /h) contribute. An event in an order-1 cut set is single-point; an event only in larger cut sets is multi-point:

Σλ      = Σ λ_i
λ_RF    = Σ_single λ_i · (1 − DC_i)                       SPFM = 1 − λ_RF / Σλ
λ_MPFL  = Σ_single λ_i · DC_i · (1 − DCl_i)
        + Σ_multi  λ_i · (1 − DCl_i)                      LFM  = 1 − λ_MPFL / (Σλ − λ_RF)
λ_DPF   = Σ over order-2 cut sets {a,b}, both orders (x,y):
              λ_x · (1 − DCl_x) · λ_y · (1 − DC_y) · T     T = the tree's missionTime (hours)
PMHF    = λ_RF + λ_DPF  (/h)

Cut sets of order ≥ 3 do not enter λ_DPF. Without a missionTime, T defaults to 10000 h and W986 is raised.

Missing diagnostic data is conservative, not optimistic. A contributing event with no diagnosticCoverage, or — once any event of the goal declares latentDiagnosticCoverage — no latentDiagnosticCoverage, is treated as coverage 0 and raises W985 (one finding per event and field). LFM is reported only when at least one contributing event declares latentDiagnosticCoverage. A DC/DCl outside 0–1 (E846) is clamped, never extrapolated.

Targets by ASIL: SPFM ≥ {B 0.90, C 0.97, D 0.99}; LFM ≥ {B 0.60, C 0.80, D 0.90}; PMHF < {B/C 1e-7, D 1e-8} /h (ASIL A: not gated). SIL-only goals gate PMHF/PFH < {SIL1 1e-5, SIL2 1e-6, SIL3 1e-7, SIL4 1e-8} /h; SPFM/LFM are reported but not gated.

Opt-in. The SPFM/LFM/PMHF roll-up is computed only if at least one contributing event declares diagnosticCoverage, and a goal whose roll-up misses its target raises W033 (warning; gate with --deny W033, promote via [profiles]). A goal without coverage data is judged on a rate-only figure instead (below), which raises W033 only when the goal declares its own target: or .syscribe.toml sets the limit.

syscribe -m model/ metrics            # table: per-goal SPFM / LFM / PMHF + pass/fail
syscribe -m model/ metrics --json     # [{id, asil, sil, spfm, lfm, pmhf, lambdaDpf, pass, verdict}]

The verdict is pass, fail, not credible, no target (a figure but no recognised asilLevel/silLevel and no target:) or n/a (not computed). metrics exits 2 when a goal fails on a gating figure (usage errors exit 1), so it can be used as a CI gate without validate --deny W033. The first-order roll-up always gates; a rate-only or PFDavg figure gates once the goal declares target: or .syscribe.toml sets the limit, and is advisory before that.

Safety targets: rate-only and demand-mode verdicts (GH #343)

Every goal with a quantified tree gets a figure, even without coverage data:

Goal Figure
continuous, with diagnosticCoverage PMHF/PFH from the first-order roll-up above (unchanged)
continuous, no coverage data PFH = exact top-event probability over missionTime ÷ missionTime, labelled rate only
target: {mode: demand, proofTestInterval: …} PFDavg = Σ over the minimal cut sets of Π λ·(1−DC)·TI^k/(k+1)
# on the SafetyGoal
target:
  mode: demand              # continuous (default) | demand
  value: 1.0e-3             # optional: overrides the table
  unit: probability         # optional: /h | probability
  proofTestInterval: 1 year

The limit is the goal's own target.value, else [reliability.targets] in .syscribe.toml, else the built-in ISO 26262 / IEC 61508 table; every report says which, because the values are your compliance decision:

[reliability]
plausibleProbability = 0.1        # default: no event should fail with p > 0.1 over the mission

[reliability.targets.sil.2]
pfh = 1.0e-6                      # pmhf/pfh (/h), pfd, spfm, lfm

A figure is not credible when an event (or the top event) fails with a probability above the plausibility bound over the mission time: λ·T is no longer small, so the figure is no longer a rate. In demand mode the test is each event's λ·(1−DC)·TI and the PFDavg itself, and a level with no PFDavg limit (the ASIL table) is no target until you give one. metrics names the largest contributor (Fussell-Vesely), the rate to check first. Record where a rate comes from with rateSource: and rateStatus: verified | secondary | unverified on the event or FMEA row (E986 otherwise); a verdict that rests on rates that are not verified or secondary says unverified rates, list FaultTreeEvent --rate-status unverified finds them, and a claimed rate above the bound is W988. metrics --sensitivity shows each event's figure and verdict with its λ ÷10 and ×10, marking those that move the verdict. audit shows the figure; safety-case adds a "quantitative target" solution node under the goal. A malformed target: is E985, a malformed [reliability] entry W989.

Tree versus campaign. inject <TestCase> --ft <FT> --consistency compares the tree with the executable model: every minimal cut set gets its executable verdict (confirmed, or conservative or a model gap when the model survives it), and the search over combinations of the composite's faults (order 2 by default, --consistency-order, at most --max-runs 500) reports every defeating set that contains no minimal cut set as missing from the tree. An FMEA row counts as the event its ftaRef names; a row without ftaRef is not in the tree. The comparison uses every minimal cut set, whatever --max-order is. Combinations the invariants cannot judge (no applicable Except under clause) are counted, make inject exit 2, and can hide a missing set. See syscribe help inject.

Generating templates

syscribe -m model/ template FaultTree      > Safety/FTA/FT-BRAKE-001.md
mkdir -p Safety/FTA/FT-BRAKE-001
syscribe -m model/ template FaultTreeGate  > Safety/FTA/FT-BRAKE-001/FTG-BRAKE-001.md
syscribe -m model/ template FaultTreeEvent > Safety/FTA/FT-BRAKE-001/FTE-BRAKE-001.md

Attack path analysis (ISO/SAE 21434 §15.7) — APA

Attack trees are the security mirror of FTA. An AttackTree substantiates a ThreatScenario (instead of a SafetyGoal) and rolls up attack feasibility (instead of a failure probability) using a weakest-link rule, so a threat's feasibility is derived from its attack paths rather than asserted as a flat rating.

Directory layout

Like FTA, gates and steps must be nested inside a subdirectory named after the AttackTree file. The validator checks for children by qualified-name prefix (W036 if empty).

Security/Attacks/
  AT-TORQUE-001.md              ← AttackTree
  AT-TORQUE-001/                ← subdir named after the tree file
    _index.md
    ATG-TORQUE-001.md           ← AttackTreeGate (root, OR)
    ATG-TORQUE-002.md           ← AttackTreeGate (AND)
    ATS-TORQUE-001.md           ← AttackStep
    ATS-TORQUE-002.md
    ATS-TORQUE-003.md

AttackTree

---
type: AttackTree
id: AT-TORQUE-001
name: "Attack tree for TS-TORQUE-001 — forged torque request"
status: approved
threatRef: TS-TORQUE-001        # required; must resolve to a ThreatScenario (E917)
---

AttackTreeGate

---
type: AttackTreeGate
id: ATG-TORQUE-001
name: "OR gate — bypass auth OR replay frame"
gateType: OR                    # AND (sequential path) | OR (alternatives) (E919)
inputs:                         # each must resolve to an ATG-*/ATS- (E920)
  - ATG-TORQUE-002
  - ATS-TORQUE-003
---

gateType must be AND or OR (E919). A gate with no inputs fires W037.

AttackStep

---
type: AttackStep
id: ATS-TORQUE-001
name: "Extract the bus authentication key"
attackFeasibility: high         # high | medium | low | very_low (E921)
---

Feasibility rank: very_low=0, low=1, medium=2, high=3.

  • An AttackStep's value is its attackFeasibility rank.
  • An AttackTreeGate AND (a sequential path — every step required) is the MIN of its children (a chain is only as feasible as its hardest step).
  • An AttackTreeGate OR (alternatives) is the MAX of its children (the attacker takes the easiest path).
  • The AttackTree's feasibility is the value of its root node — the one gate/step of the tree that no other gate lists in its inputs: (file order does not matter; with no unique root the roll-up is not computed), mapped back to a label.

If the computed feasibility differs from the linked ThreatScenario.attackFeasibility, the validator emits W035 naming computed vs declared (gate with --deny W035, promote via [profiles]).

Worked example. Root OR over [AND(high, low), medium]: the AND path is min(high, low) = low; the root OR is max(low, medium) = medium. A linked threat declaring high therefore raises one W035 (computed medium ≠ declared high).


Freedom From Interference (ISO 26262-9 §7) — ffiRationale / W034

Dependent-failure analysis flags mixed-criticality elements that share a resource without a freedom-from-interference (FFI) / partitioning argument. Two elements share a resource when both are allocated to the same target — collected from allocatedTo:, allocatedFrom:, and Allocation elements alike. Each element carries an integrity tag (asilLevel, else silLevel → SIL<n>, else QM); two sources on one target are mixed when their tags differ (including classified vs QM).

A mixed pair raises W034 unless an FFI argument is present — either the target or at least one of the two sources declares a non-empty ffiRationale: string, or carries a breakdownAdr: that resolves to an accepted ADR:

---
type: PartDef
name: HostECU
domain: hardware
# documents the partitioning argument that excuses the mixed-criticality sharing:
ffiRationale: "MPU spatial partitioning + AUTOSAR OS timing protection isolate the ASIL D and QM partitions (ISO 26262-6 §7.4.9)."
---

Opt-in. The check is dormant unless at least one element declares asilLevel or silLevel. W034 is a warning (gate with --deny W034, promote via [profiles]).

Deferred: surfacing these shared resources as candidate cybersecurity attack surfaces for the co-analysis view is not yet implemented.


Confirmation measures & DIA/CIA responsibility (ISO 26262-2 §6 / -8 §5 / ISO/SAE 21434 §7)

Assessors check two things early in a distributed-development audit: who is accountable for each work product (the DIA/CIA split), and the confirmation measures — confirmation reviews, functional-safety audit and assessment, cybersecurity assessment — with their required independence level (I1–I3). Both are represented in the model and both checks are opt-in.

responsibility: — the DIA/CIA split (W038)

Add responsibility: (a free-text party/organisation, e.g. OEM or Supplier-X) to any element. A non-draft work product (Requirement, PartDef, Part, SafetyGoal, CybersecurityGoal) with no responsibility: raises W038 — but only once the model has adopted the practice (at least one element declares responsibility:). A model that has not adopted DIA/CIA tracking emits zero W038.

type: PartDef
name: BrakeController
status: approved
responsibility: OEM

ConfirmationMeasure (CM-*) and required independence (W039)

type: ConfirmationMeasure
id: CM-BRK-001
name: "Independent functional-safety assessment of the braking goal"
status: completed                 # planned | in_progress | completed  (else E924)
measureType: functional_safety_assessment
#   confirmation_review | functional_safety_audit |
#   functional_safety_assessment | cybersecurity_assessment   (else E849)
independenceLevel: I3             # I1 | I2 | I3                (else E850)
confirms:                         # work product ref(s) (else E851); goals, hazards, requirements, FaultTree, FMEASheet, TARASheet, ADR, Argument, TestPlan, Allocation (else E860)
  - SG-BRK-001

Structural errors: E847 (missing id/name/status), E848 (id not CM-*), E849/E850/E924 (invalid measureType/independenceLevel/status), E851 (unresolved confirms:).

W039 flags a high-integrity item that lacks its required independent assessment: an asilLevel: D or silLevel: 3/4 SafetyGoal/native Requirement with no I3 functional_safety_assessment confirming it, a calLevel: CAL4 CybersecurityGoal with no I3 cybersecurity_assessment, or a calLevel: CAL3 CybersecurityGoal with no I2-or-I3 cybersecurity_assessment. Lower levels are not gated. Opt-in: W039 is dormant unless at least one ConfirmationMeasure exists, so bundled models stay silent. Both W038 and W039 are warnings, gateable (--deny W038 / --deny W039) and profile-promotable.

syscribe -m model/ template ConfirmationMeasure   # ready-to-fill skeleton

Safety case — GSN argument layer (Argument, AssumptionOfUse) and the safety-case view

The Goal Structuring Notation (GSN) argument layer makes the safety argument — not just the hazards and goals — a first-class, validated part of the model (issue #20). It complements the pre-existing hazard/goal layer (HazardousEvent, SafetyGoal) and the FMEA failure layer.

Argument (ARG-*) — a GSN node

---
type: Argument
id: ARG-BRK-001
name: "Argue over independent torque monitoring"
status: approved
argumentType: strategy   # claim | strategy | solution   (absent → claim; else E854)
supports: SG-BRK-001     # the SafetyGoal or parent Argument argued for (string or list; else E855)
evidence:                # Requirement / TestCase / sub-Argument / AssumptionOfUse refs (else E855)
  - ARG-BRK-002
  - REQ-BRK-001
---

id/name/status are required (else E852); the id must match ARG-* (else E853). A claim/strategy Argument with both empty supports and empty evidence is an orphan GSN node → W040.

---
type: AssumptionOfUse
id: AOU-BRK-001
name: "Integrator provides a redundant torque sensor"
status: approved
appliesTo: SG-BRK-001    # the SafetyGoal / Argument / Requirement it constrains (string or list; else E858)
---

id/name/status are required (else E856); the id must match AOU-* (else E857).

The safety-case view

syscribe -m model/ safety-case              # all top SafetyGoals
syscribe -m model/ safety-case SG-BRK-001   # only the named goal
syscribe -m model/ safety-case --json       # machine-readable tree

For each SafetyGoal the view renders the GSN tree: the goal → the Arguments whose supports names it (recursing into sub-Arguments) → each Argument's evidence (Requirements and TestCases as leaves, with the TestCase's ingested verdict when a results sidecar is present) → any AssumptionOfUse that appliesTo the goal/argument.

It also folds in the implicit chain that already exists without explicit Argument nodes: SafetyGoal ← Requirement (derivedFromSafetyGoal) ← derivedChildren (transitively) ← TestCase (verifies) — for every goal, including goals that have Arguments (a requirement an Argument cites is shown once). That makes the view immediately useful on models that have goals + requirements + tests but no Argument nodes yet, and stops a partial argument from looking complete. Nodes with no supporting evidence are marked [UNDEVELOPED], every goal shows a SUPPORTED/INCOMPLETE/FAILING verdict, and a Completeness: summary counts goals, requirements without tests, test verdicts and undeveloped nodes. An Argument cycle is E881; a solution with no evidence: is W861. The view is read-only and exits 0 (a notice when there is no SafetyGoal).

[SafetyGoal] SG-BRK-001 — Prevent unintended acceleration
├── [strategy] ARG-BRK-001 — Argue over independent torque monitoring
│   ├── [solution] ARG-BRK-002 — Torque monitor is verified by test
│   │   └── [evidence:TestCase] TC-BRK-001 — ... [pass]
│   └── [evidence:Requirement] REQ-BRK-001 — ...
└── [AoU] AOU-BRK-001 — Integrator provides a redundant torque sensor
syscribe -m model/ template Argument          # ready-to-fill skeletons
syscribe -m model/ template AssumptionOfUse

Failure Mode and Effects Analysis (FMEA)

FMEA uses the same exploded container pattern as TARA. One FMEASheet file; the parser synthesises a first-class FMEAEntry for each row.

---
type: FMEASheet
id: FMEA-BRAKE-001
name: "FMEA — Brake Controller"
status: draft
entries:
  - id: FM-BRAKE-001
    ref: Braking::BrakeController
    failureMode: "Loss of output signal"
    effect: "No braking force applied"
    cause: "Software exception in control loop"
    fmeaSeverity: 9     # 1–10
    occurrence: 3       # 1–10
    detection: 4        # 1–10
    # rpn: 108          # auto-computed: 9 × 3 × 4 = 108
    recommendedAction: "Add independent watchdog monitor"
    satisfies: REQ-BRAKE-001
---

RPN is computed automatically from fmeaSeverity × occurrence × detection if all three are present. W903 fires when RPN > 100 and no recommendedAction is set.

Two row-integrity checks keep a sheet honest:

  • Every row needs an id: (FM-*). A row without one cannot become an FMEAEntry, so it is dropped from validation and fmea report — and reported as error E923 on the sheet, naming the row's position in entries: and its failureMode:.
  • The computed RPN wins. When fmeaSeverity, occurrence and detection are all present, an explicit rpn: is ignored in favour of S × O × D; if it disagrees, warning W928 names the row and both values so the stale number can be corrected or removed. An explicit rpn: on a row missing a factor is used as-is.

Injectable failure modes — injection:

A failure mode can carry a machine-readable fault model so that scenarios of an executable composite (System composition) can inject it. injection: is a list on an FMEA row (and on a FaultTreeEvent); the row's ref: names the part definition that fails, and the element's id is the fault's id:

entries:
  - id: FM-LINK-001
    ref: Link::Transmitter
    failureMode: "command lost"
    injection: [{kind: drop, port: out}]
  - id: FM-LINK-002
    ref: Link::Transmitter
    failureMode: "level sensor stuck"
    injection: [{kind: stuck, variable: level, value: "3"}]
kind Fields Effect while injected
stuck variable, value writes to the variable are discarded; it holds value
offset variable, by every written value is increased by by (same dimension)
silent — the part fails silent: no event, timer or message; cannot be cleared
drop port, optional event messages through the port are lost
delay port, by, optional event messages through the port arrive by later
corrupt port, field, value, optional event the payload field is replaced
parameter parameter, value an in-process plant's parameter takes value until the fault is cleared (GH #340)

On an in-process plant part (plant:, see In-process plants) stuck and offset name one of its outputs and act on every read from the moment of injection, and silent freezes the plant: it is no longer stepped or read, so the machines keep its last outputs.

A row may be gated like any element with its own appliesWhen: (- {id: FM-X-001, ref: Pkg::Part, appliesWhen: Features::Opt, …}); it is then absent from products without the feature, so a ref to a gated element raises no W904 there. A fault value may be a feature-parameter placeholder, value: "{{Features::Grid.nominalHz}}"; a run with --config uses the Configuration's binding, validate the parameter's default.

part: names an instance of the composite; without it the fault applies to every part whose definition is, or specialises, ref. A malformed list is E936. Scenarios use Given|When fault FM-LINK-001 is injected and When fault FM-LINK-001 is cleared (E937 for an unknown id); see docs/design/fault-injection.md.

Fault-injection campaign — inject

syscribe -m model/ inject <composite|TestCase> [--ft <FT-id>] [--max-order N] [--fmea <sheet>] runs the @invariant scenarios of a composite under every single fault and (with --ft) every minimal cut set of a fault tree up to the given order, and says which fault sets the design survives:

@invariant
Scenario: the receiver never sees more than the nominal value
  When tx receives Tick
  Then rx.got <= 7

An invariant can state the safe state precisely and over time (GH #342, spec §8.12.8): Where <name> is <expression> names it once, Except under <fault> [and <fault>…]: <expression> gives the degraded safe state for the faults that make part of it impossible (a welded relay cannot open), and Then within 2 s the safe state holds, Then always … and Then never … check it at every settled instant rather than once:

Feature: protection
  Where the safe state is pwm.on == 0 and relayA.closed == 0 and relayB.closed == 0
  Except under FM-RLY-001: pwm.on == 0 and relayB.closed == 0
  Except under FM-RLY-002: pwm.on == 0 and relayA.closed == 0
  Except under FM-RLY-001 and FM-RLY-002: pwm.on == 0

  @invariant
  Scenario: after a grid loss the safe state is reached within 2 s and kept
    When grid receives Lost
    Then within 2 s the safe state holds
    When 10 s elapses

A fault no clause names keeps the full property. A set to which several clauses apply needs a clause that covers them all; without one the run is an error, "no applicable degraded clause", not a defeat. A set whose invariants held only in a degraded clause is reported survived (degraded).

The invariants must pass without faults first; each fault set is then injected at time 0 and the invariants run unchanged. survived / defeated / error are reported per set with the failing invariant and step; the report also lists the FMEA rows of the composite's parts that were exercised, those with a fault model that were not, and those with none (prose only). Exit status 2 on a defeat unless --report-only. --config <C> runs it on one Configuration, --record keeps it as evidence and --report <file> writes it for an assessor (see below). See syscribe help inject and docs/design/fault-injection.md.

Residual-risk decisions — ResidualRisk

A defeated fault set is the most important result of a campaign: a combination of failures under which a stated safety property is violated. Record the campaign and the decision on each defeat in the model, so an assessor can ask "which defeats are accepted, by whom, why and with what rate" and get an answer, and so a new defeat stands out from the known ones (GH #341).

syscribe -m model/ inject TC-PROT-001 --ft FT-001 --max-order 3 --record --report-only   # keep the campaign in .syscribe/campaigns.json
syscribe -m model/ inject TC-PROT-001 --ft FT-001 --record --run rc1 --report campaign.md # a named run, plus a report for the assessor
syscribe -m model/ results campaigns                                                     # the recorded histories
syscribe -m model/ results campaigns diff TC-PROT-001                                    # what changed between the two latest

Every defeat in the latest record then needs a decision, one ResidualRisk per fault set:

---
type: ResidualRisk
id: RISK-BRAKE-001
name: Both wheel-speed sensors lost together
status: accepted              # proposed | accepted | mitigated | rejected
faultSet: [FTE-BRAKE-003, FTE-BRAKE-004]
goal: SG-BRAKE-001
rationale: "Independent harnesses; only a connector failure loses both, covered by REQ-BRAKE-077."
mitigatedBy: [REQ-BRAKE-077]
approvedBy: jane
reviewDate: 2026-10-12
expires: 2027-10-12
campaignHash: 3f9a1c0be2d4   # the hash `inject` printed
---

validate reads the latest record of each campaign (made without --config; validate --config C reads those made with C):

Code When
W940 a defeated set has no proposed or accepted decision explaining it (on the composite)
W941 a decision the campaign contradicts: accepted but the design now survives the set, or mitigated but it still defeats
W942 campaignHash is not the current hash of the composite: review the decision
W943 an accepted or proposed decision past its expires
W944 the recorded campaign ran on an older composite (or the composite no longer builds): run the recorded command again
W945 .syscribe/campaigns.json cannot be read; nothing is judged and --record refuses to overwrite it
W946 a decision names a set the latest record did not run (a narrower re-record dropped it)
E942 / E943 / E944 a malformed decision / a faultSet, goal or mitigatedBy that resolves to nothing / one of the wrong kind

Gate CI on new defeats with validate --deny W940. The rate of a set comes from the fault-tree events' failureRate, not from the decision; inject --report shows it next to the decision. safety-case shows a solution node per campaign under the --ft tree's top-event goal and the goals the decisions name, undeveloped while a defeat is unexplained; audit --config C lists the unexplained defeats, and plain audit counts them per configuration. See spec §12.14.

Generating a template

syscribe -m model/ template FMEASheet > Safety/FMEA-BRAKE-001.md

Linking analysis to requirements

Safety and security analysis produces goals and findings that must be elaborated into traceable requirements. Two dedicated fields record the upstream motivation for each requirement.

Safety requirements — derivedFromSafetyGoal

type: Requirement
id: REQ-BRAKE-HYD-001
name: "Brake hydraulic pressure shall be maintained within 50 ms of loss detection"
reqDomain: software
status: draft
derivedFromSafetyGoal: SG-BRAKE-001   # the SafetyGoal that motivated this requirement
breakdownAdr: ADR-BRAKE-001
  • E832 — derivedFromSafetyGoal must resolve to a SafetyGoal element.
  • E841 — the SafetyGoal carries an asilLevel/silLevel; the requirement must set the same field (same or lower level).
  • W808 — if the requirement's level is lower than the goal's, a breakdownAdr is required to justify the ASIL/SIL decomposition.
  • W805 — fires on a SafetyGoal that has no Requirement pointing back to it, indicating the goal has not yet been elaborated into a traceable requirement.

Integrity level propagation

Once a SafetyGoal carries an integrity level (asilLevel, silLevel, or plLevel), that level must flow through every downstream element in the traceability chain:

Link direction Rule
SafetyGoal → Requirement (derivedFromSafetyGoal) E841 if missing; W808 if lower without ADR
Requirement → child Requirement (derivedFrom) E842 if missing; W808 if lower without ADR
Requirement → architecture element (satisfies) E843 if missing; W808 if lower without ADR

Same level — no additional action required beyond the normal breakdownAdr (E310).

Lower level — valid only when the architecture applies redundancy or independence arguments (ASIL decomposition per ISO 26262-9 or SIL decomposition per IEC 61508-2 §7.4.9). Set breakdownAdr: to an accepted ADR that documents the decomposition rationale.

Security requirements — derivedFromCybersecurityGoal

type: Requirement
id: REQ-SEC-CAN-001
name: "ECU shall authenticate all CAN frames on the safety bus using CMAC"
reqDomain: software
status: draft
verificationMethod: test
derivedFromCybersecurityGoal: CSG-SYS-001  # the CybersecurityGoal that motivated this requirement
breakdownAdr: ADR-SEC-CAN-001
  • E831 — derivedFromCybersecurityGoal must resolve to a CybersecurityGoal element.
  • W804 — fires on a CybersecurityGoal that has no Requirement pointing back to it.
  • derivedFromSecurityGoal: is a legacy alias for derivedFromCybersecurityGoal:, still honored for backward compatibility — use the current name in new models.

Development process chain

The full trace from a threat or hazard identification through to a verified implementation:

┌─────────────────────────────────────────────────────────────────────┐
│ Safety (ISO 26262 / IEC 61508 / ISO 13849)                          │
│                                                                     │
│  HazardousEvent  →  SafetyGoal                                      │
│   (HE-*)             (SG-*)  ←────── derivedFromSafetyGoal ──────┐  │
│                         │                                         │  │
│                         └──── topEvent ──── FaultTree             │  │
│                                              (FT-*)               │  │
└─────────────────────────────────────────────────────────────────────┘
                                                                    │
┌─────────────────────────────────────────────────────────────────── │ ┐
│ Security (ISO/SAE 21434)                                           │  │
│                                                                    │  │
│  TARASheet → CybersecurityGoal ←── derivedFromCybersecurityGoal ───┐   │  │
│               (CSG-*)                                          │   │  │
│                  │ implementsGoals ←── SecurityControl         │   │  │
└─────────────────────────────────────────────────────────────────── │ ┘
                                                                    │  │
┌─────────────────────────────────────────────────────────────────── │ ─┘
│ Requirements & Architecture                                        │   │
│                                                                    │   │
│  Requirement (REQ-*) ─────────────────────────────────────────────┘   │
│   derivedFrom: parent REQ-*                                            │
│   breakdownAdr: ADR-*                                         ─────────┘
│        │
│        └── satisfies: ←── Part / PortDef / SecurityControl
│                                 │
│                                 └── allocatedTo: HW element
│
│  TestCase (TC-*)  verifies: REQ-*
└────────────────────────────────────────────────────────────────────────

Traceability queries

# Show a safety goal and its integrity level
syscribe -m model/ show SG-BRAKE-001

# What requirements were derived from this goal?
syscribe -m model/ refs SG-BRAKE-001

# Full trace from a safety requirement upward and downward
syscribe -m model/ trace REQ-BRAKE-HYD-001

# What architecture elements satisfy a requirement?
syscribe -m model/ why REQ-BRAKE-HYD-001

# Which test cases cover a requirement?
syscribe -m model/ who-verifies REQ-BRAKE-HYD-001

# All elements that reference a cybersecurity goal
syscribe -m model/ refs CSG-SYS-001

Validation rules summary

Code Severity Description
E800 Error HazardousEvent missing required field (id, name, status)
E801–E803 Error ISO 26262 risk parameter out of valid range (S/E/C)
E804 Error HazardousEvent id does not match HE-* pattern
E805 Error SafetyGoal missing required field
E806 Error SafetyGoal id does not match SG-* pattern
E833–E836 Error IEC 61508 risk parameter out of valid range
E837 Error SafetyGoal plLevel not in a–e
E825 Error hazardousEvents ref does not resolve to a HazardousEvent
E831 Error derivedFromCybersecurityGoal does not resolve to a CybersecurityGoal
E832 Error derivedFromSafetyGoal does not resolve to a SafetyGoal
E841 Error Element linked via derivedFromSafetyGoal is missing asilLevel/silLevel when the SafetyGoal has one
E842 Error Element linked via derivedFrom is missing asilLevel/silLevel when the parent carries one
E843 Error Element linked via satisfies is missing asilLevel/silLevel when the requirement carries one
E902 Error FaultTree.topEvent does not resolve to a SafetyGoal
E906 Error FaultTreeGate.inputs ref is not a gate or event
W006 Warning silLevel and asilLevel both set on the same element — incompatible standards
W800 Warning HazardousEvent not referenced by any SafetyGoal (not raised for QM-rated events)
W801 Warning SafetyGoal has no integrity level (asilLevel, silLevel, or plLevel)
W806 Warning SafetyGoal has no hazardousEvents — not grounded in any hazard analysis
W804 Warning CybersecurityGoal has no Requirement with derivedFromCybersecurityGoal
W805 Warning SafetyGoal has no Requirement with derivedFromSafetyGoal
W808 Warning Element's integrity level is lower than its source (derivedFromSafetyGoal, derivedFrom, or satisfies) but no breakdownAdr is set
E878 Error Decomposition children are not an allowed ISO 26262-9 ASIL pair
E879 Error decomposedFrom: is not A–D or is lower than the element's own asilLevel
E880 Error ftti: is not a number with unit ns/us/ms/s/min/h
W811 Warning SafetyGoal asilLevel is lower than the ASIL derived from its HazardousEvents
W812 Warning SafetyGoal at ASIL C/D or SIL 3/4 lacks safeState: or ftti:
W813 Warning HazardousEvent has a partial S/E/C set
W814 Warning HazardousEvent mixes ISO 26262 and IEC 61508 parameters

Safety diagrams — fault tree, attack tree and GSN

Three Diagram kinds draw the safety analyses above straight from the model (GH #223). They are derive-only: give a diagramKind: and a subject: and nothing else.

---
type: Diagram
name: FaultTreeEngine
diagramKind: FaultTree          # FaultTree | AttackTree | SafetyCase (alias GSN)
subject: Safety::FTA::FT-ENG-001
---
Kind Subject What it shows
FaultTree a FaultTree, or the SafetyGoal it analyses IEC 61025 gate symbols (AND, OR, XOR, NOT, inhibit), events by eventKind (basic circle, undeveloped diamond, house), λ and probability on every event, single points of failure (red) and dual-point cut-set members (amber), the minimal-cut-set count as a badge and the exact top-event probability on the root — the numbers of fault-tree analyze. A gate cycle still draws the structure, the root saying the analysis is unavailable.
AttackTree an AttackTree, or the ThreatScenario it substantiates gates and steps coloured by rolled-up feasibility (high red, medium amber, low green, unscored grey), the easiest path drawn heavier, the root saying whether it matches the threat's declared feasibility (W035 badge when not).
SafetyCase a SafetyGoal, an Argument, or a package of goals the GSN argument of safety-case: goals, strategies, solutions (test cases), context, justification and assumption nodes, a diamond under every undeveloped claim, status tones, the goal verdict on the root.

A wrong subject type is W418; an include:/exclude: entry naming nothing is W417. Each node links to its element: in the web UI the detail panel of a FaultTree, AttackTree, SafetyGoal, Argument or ThreatScenario embeds the diagram itself (no Diagram element needed) and a click on a node opens that element. The New diagram dialog offers the three kinds.

From the command line:

syscribe -m model/ diagram export Diagrams::FaultTreeEngine --format svg|mermaid|plantuml|dot
syscribe -m model/ fault-tree render FT-ENG-001 --format mermaid|dot|svg|plantuml
syscribe -m model/ safety-case SG-ENG-001 --format dot|mermaid     # with the ingested test verdicts

fault-tree render without --format and safety-case without --format keep their original text output.

Hazard-to-test traceability, zones and the threat graph

Three more derive-only kinds draw how the analyses connect (GH #223). Same two lines of frontmatter, same node overlay, same writers.

---
type: Diagram
name: TraceabilityEngine
diagramKind: Traceability       # Traceability | ZoneConduit | ThreatGraph
subject: Safety::HARA::SG-ENG-001
---
Kind Subject What it shows
Traceability a SafetyGoal, HazardousEvent, Requirement or package HazardousEvent ← SafetyGoal ← Requirement ← … ← TestCase, with each goal's fault tree and arguments alongside. Colour is the roll-up of what is below a node (a failing test or a gap red, an unverified branch amber, a passing one green), the label shows its ASIL and status, and gaps are red badges that name the finding: W002/W003 no test, W305 no integration test, W300 unsatisfied, no requirement, no goal.
ZoneConduit a package of zones, a Zone or a Conduit each IEC 62443 zone a compound node holding its parts and the security controls allocated to them, labelled SL target / achieved (red with an SL gap badge when short, W950); each conduit an edge labelled CD-… · SL achieved/required, red, heavy and dashed when weak (W951).
ThreatGraph a package or TARASheet, or one threat, damage scenario, asset, goal or control ThreatScenario → DamageScenario → Asset → CybersecurityGoal → SecurityControl. Threats are coloured by their risk under the configured [cyber] method; a goal no control implements carries W802, a threat no goal treats no goal.

The detail panel of a hazardous event, goal, zone, conduit, threat, damage scenario, asset, cybersecurity goal or control embeds the diagram, and the New diagram dialog offers all three. From the command line:

syscribe -m model/ hara trace [SG-ENG-001] --format dot|mermaid|plantuml|svg   # with the ingested test verdicts
syscribe -m model/ zones --format dot|mermaid|plantuml|svg                     # the whole model's zones and conduits
syscribe -m model/ cyber-risk --format dot|mermaid|plantuml|svg                # the threat graph (md|html|json keep the heat table)
syscribe -m model/ diagram export Diagrams::ZoneConduitEngine --format svg|mermaid|plantuml|dot
syscribe -m model/ connectivity SG-ENG-001                                     # walks hazardousEvents, topEvent, threatRef, gate inputs, ...

zones --coverage lists a control against a zone when the control is allocated (an Allocation element, allocatedTo:) to one of the zone's parts, to the zone or to a conduit touching it, or a touching conduit names it in implementedBy:. A zone's members: can only be parts (E955), so the earlier rule that looked for a SecurityControl among the members never matched and every control column read —.